aboutsummaryrefslogtreecommitdiff
path: root/vswitchd/ovs-vswitchd.8.in
blob: 41413b9699c8ee3940a762acbe9cba71c3aaaa43 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
.\" -*- nroff -*-
.de IQ
.  br
.  ns
.  IP "\\$1"
..
.TH ovs\-vswitchd 8 "June 2009" "Open vSwitch" "Open vSwitch Manual"
.\" This program's name:
.ds PN ovs\-vswitchd
.\" SSL peer program's name:
.ds SN ovs\-controller
.
.SH NAME
ovs\-vswitchd \- Open vSwitch daemon
.
.SH SYNOPSIS
\fBovs\-vswitchd \fR[\fIdatabase\fR]
.
.SH DESCRIPTION
A daemon that manages and controls any number of Open vSwitch switches
on the local machine.
.PP
The \fIdatabase\fR argument specifies how \fBovs\-vswitchd\fR connects
to \fBovsdb\-server\fR.  The default is \fBunix:@RUNDIR@/db.sock\fR.
The following forms are accepted:
.so ovsdb/remote-active.man
.so ovsdb/remote-passive.man
.PP
\fBovs\-vswitchd\fR retrieves its configuration from \fIdatabase\fR at
startup.  It sets up Open vSwitch datapaths and then operates
switching across each bridge described in its configuration files.  As
the database changes, \fBovs\-vswitchd\fR automatically updates its
configuration to match.
.PP
Upon receipt of a SIGHUP signal, \fBovs\-vswitchd\fR reopens its log
file, if one was specified on the command line.
.PP
\fBovs\-vswitchd\fR switches may be configured with any of the following
features:
.
.IP \(bu
L2 switching with MAC learning.
.
.IP \(bu
NIC bonding with automatic fail-over and source MAC-based TX load
balancing ("SLB").
.
.IP \(bu
802.1Q VLAN support.
.
.IP \(bu
Port mirroring, with optional VLAN tagging.
.
.IP \(bu
NetFlow v5 flow logging.
.
.IP \(bu
sFlow(R) monitoring.
.
.IP \(bu
Connectivity to an external OpenFlow controller, such as NOX.
.
.PP
Only a single instance of \fBovs\-vswitchd\fR is intended to run at a time.
A single \fBovs\-vswitchd\fR can manage any number of switch instances, up
to the maximum number of supported Open vSwitch datapaths.
.PP
\fBovs\-vswitchd\fR does all the necessary management of Open vSwitch datapaths
itself.  Thus, external tools, such \fBovs\-dpctl\fR(8), are not needed for
managing datapaths in conjunction with \fBovs\-vswitchd\fR, and their use
to modify datapaths when \fBovs\-vswitchd\fR is running can interfere with
its operation.  (\fBovs\-dpctl\fR may still be useful for diagnostics.)
.PP
An Open vSwitch datapath kernel module must be loaded for \fBovs\-vswitchd\fR
to be useful.  Please refer to the \fBINSTALL.Linux\fR file included in the
Open vSwitch distribution for instructions on how to build and load
the Open vSwitch kernel module.
.PP
.SH OPTIONS
.IP "\fB\-\-mlockall\fR"
Causes \fBovs\-vswitchd\fR to call the \fBmlockall()\fR function, to
attempt to lock all of its process memory into physical RAM,
preventing the kernel from paging any of its memory to disk.  This
helps to avoid networking interruptions due to system memory pressure.
.IP
Some systems do not support \fBmlockall()\fR at all, and other systems
only allow privileged users, such as the superuser, to use it.
\fBovs\-vswitchd\fR emits a log message if \fBmlockall()\fR is
unavailable or unsuccessful.
.
.ds DD \
\fBovs\-vswitchd\fR detaches only after it has connected to the \
database, retrieved the initial configuration, and set up that \
configuration.
.so lib/daemon.man
.SS "Public Key Infrastructure Options"
.so lib/ssl.man
.so lib/ssl-bootstrap.man
.so lib/vlog.man
.so lib/common.man
.so lib/leak-checker.man
.
.SH "RUNTIME MANAGEMENT COMMANDS"
\fBovs\-appctl\fR(8) can send commands to a running
\fBovs\-vswitchd\fR process.  The currently supported commands are
described below.  The command descriptions assume an understanding of
how to configure Open vSwitch.
.SS "GENERAL COMMANDS"
.IP "\fBexit\fR"
Causes \fBovs\-vswitchd\fR to gracefully terminate.
.IP "\fBcoverage/log\fR"
Logs coverage counters at level warn.
.IP "\fBqos/show\fR \fIinterface\fR"
Queries the kernel for Quality of Service configuration and statistics
associated with the given \fIinterface\fR.
.IP "\fBcfm/show\fR [\fIinterface\fR]"
Displays detailed information about Connectivity Fault Management
configured on \fIinterface\fR.  If \fIinterface\fR is not specified,
then displays detailed information about all interfaces with CFM
enabled.
.SS "BRIDGE COMMANDS"
These commands manage bridges.
.IP "\fBfdb/flush\fR [\fIbridge\fR]"
Flushes \fIbridge\fR MAC address learning table, or all learning tables
if no \fIbridge\fR is given.
.IP "\fBfdb/show\fR \fIbridge\fR"
Lists each MAC address/VLAN pair learned by the specified \fIbridge\fR,
along with the port on which it was learned and the age of the entry,
in seconds.
.IP "\fBbridge/reconnect\fR [\fIbridge\fR]"
Makes \fIbridge\fR drop all of its OpenFlow controller connections and
reconnect.  If \fIbridge\fR is not specified, then all bridges drop
their controller connections and reconnect.
.IP
This command might be useful for debugging OpenFlow controller issues.
.
.IP "\fBbridge/dump\-flows\fR \fIbridge\fR"
Lists all flows in \fIbridge\fR, including those normally hidden to
commands such as \fBovs\-ofctl dump\-flows\fR.  Flows set up by mechanisms
such as in-band control and fail-open are hidden from the controller
since it is not allowed to modify or override them.
.SS "BOND COMMANDS"
These commands manage bonded ports on an Open vSwitch's bridges.  To
understand some of these commands, it is important to understand a
detail of the bonding implementation called ``source load balancing''
(SLB).  Instead of directly assigning Ethernet source addresses to
slaves, the bonding implementation computes a function that maps an
48-bit Ethernet source addresses into an 8-bit value (a ``MAC hash''
value).  All of the Ethernet addresses that map to a single 8-bit
value are then assigned to a single slave.
.IP "\fBbond/list\fR"
Lists all of the bonds, and their slaves, on each bridge.
.
.IP "\fBbond/show\fR \fIport\fR"
Lists all of the bond-specific information about the given bonded
\fIport\fR: updelay, downdelay, time until the next rebalance.  Also
lists information about each slave: whether it is enabled or disabled,
the time to completion of an updelay or downdelay if one is in
progress, whether it is the active slave, the MAC hashes assigned to
the slave, and the MAC learning table entries that hash to each MAC.
Any LACP information related to this bond may be found using the
\fBlacp/show\fR command.
.IP "\fBbond/migrate\fR \fIport\fR \fIhash\fR \fIslave\fR"
Only valid for SLB bonds.  Assigns a given MAC hash to a new slave.
\fIport\fR specifies the bond port, \fIhash\fR the MAC hash to be
migrated (as a decimal number between 0 and 255), and \fIslave\fR the
new slave to be assigned.
.IP
The reassignment is not permanent: rebalancing or fail-over will
cause the MAC hash to be shifted to a new slave in the usual
manner.
.IP
A MAC hash cannot be migrated to a disabled slave.
.IP "\fBbond/set\-active\-slave\fR \fIport\fR \fIslave\fR"
Sets \fIslave\fR as the active slave on \fIport\fR.  \fIslave\fR must
currently be enabled.
.IP
The setting is not permanent: a new active slave will be selected
if \fIslave\fR becomes disabled.
.IP "\fBbond/enable\-slave\fR \fIport\fR \fIslave\fR"
.IQ "\fBbond/disable\-slave\fR \fIport\fR \fIslave\fR"
Enables (or disables) \fIslave\fR on the given bond \fIport\fR, skipping any
updelay (or downdelay).
.IP
This setting is not permanent: it persists only until the carrier
status of \fIslave\fR changes.
.IP "\fBbond/hash\fR \fImac\fR [\fIvlan\fR] [\fIbasis\fR]"
Returns the hash value which would be used for \fImac\fR with \fIvlan\fR
and \fIbasis\fR if specified.
.
.IP "\fBlacp/show\fR [\fIport\fR]"
Lists all of the LACP related information about the given \fIport\fR:
active or passive, aggregation key, system id, and system priority.  Also
lists information about each slave: whether it is enabled or disabled,
whether it is attached or detached, port id and priority, actor
information, and partner information.  If \fIport\fR is not specified,
then displays detailed information about all interfaces with CFM
enabled.
.
.so ofproto/ofproto-unixctl.man
.so lib/vlog-unixctl.man
.so lib/stress-unixctl.man
.SH "SEE ALSO"
.BR ovs\-appctl (8),
.BR ovs\-brcompatd (8),
.BR ovsdb\-server (1),
\fBINSTALL.Linux\fR in the Open vSwitch distribution.