diff options
author | Ethan Jackson <ethan@nicira.com> | 2011-05-12 15:28:43 -0700 |
---|---|---|
committer | Ethan Jackson <ethan@nicira.com> | 2011-05-20 15:53:29 -0700 |
commit | 93b8df3853659238df58b1e1e69a0c5608e208f8 (patch) | |
tree | 713d6a935a5f94bf27930dee9f2435e14953bb7e /utilities/ovs-vsctl.8.in | |
parent | 84c5d450aaefb73b944506afe9f2fe05fa0612bf (diff) |
cfm: Remove Maintenance_Point and Monitor tables.
In an effort to make CFM easier to understand and configure, this
patch removes the Maintenance_Point and Monitor tables from the
database. As a consequence, users will only be able to configure
one remote maintenance point. Furthermore, before this patch each
remote maintenance point maintained its own separate fault flag in
the database. This flag is no longer reported, users will need to
infer the fault status from the global CFM fault flag.
Diffstat (limited to 'utilities/ovs-vsctl.8.in')
-rw-r--r-- | utilities/ovs-vsctl.8.in | 19 |
1 files changed, 4 insertions, 15 deletions
diff --git a/utilities/ovs-vsctl.8.in b/utilities/ovs-vsctl.8.in index fcfec024..97944dfb 100644 --- a/utilities/ovs-vsctl.8.in +++ b/utilities/ovs-vsctl.8.in @@ -483,11 +483,6 @@ identified by port name. .IP "\fBQueue\fR" Configuration for one queue within a \fBQoS\fR configuration. Records may only be identified by UUID. -.IP "\fBMonitor\fR" -Connectivity Monitoring attached to an \fBInterface\fR. Records may be -identified by \fBInterface\fR name. -.IP "\fBMaintenance_Point\fR" -Maintenance Point managed by a \fBMonitor\fR. .IP "\fBMirror\fR" A port mirroring configuration attached to a bridge. Records may be identified by mirror name. @@ -783,19 +778,13 @@ their UUIDs, then "\fBovs\-vsctl destroy Queue \fIuuid1\fR \fIuuid2\fR" to destroy each of them.) .SS "Connectivity Monitoring" .PP -Create a Monitor which manages a couple of remote Maintenance Points on eth0. +Monitor connectivity to a remote maintenance point on eth0. .IP -.B "ovs\-vsctl \-\- set Interface eth0 Monitor=@newmon \(rs" -.IP -.B "\-\- \-\-id=@newmon create Monitor mpid=1 remote_mps=@mp2,@mp3 \(rs" -.IP -.B "\-\- \-\-id=@mp2 create Maintenance_Point mpid=2 \(rs" -.IP -.B "\-\- \-\-id=@mp3 create Maintenance_Point mpid=3" +.B "ovs\-vsctl set Interface eth0 cfm_mpid=1 cfm_remote_mpid=2" .PP -Deconfigure the Monitor record from above: +Deconfigure connectivity monitoring from above: .IP -.B "ovs\-vsctl clear Interface eth0 Monitor" +.B "ovs\-vsctl clear Interface eth0 cfm_mpid cfm_remote_mpid" .SS "NetFlow" .PP Configure bridge \fBbr0\fR to send NetFlow records to UDP port 5566 on |