authorBen Pfaff <blp@nicira.com>2011-05-11 12:13:10 -0700
committerBen Pfaff <blp@nicira.com>2011-05-11 12:35:09 -0700
commitabe529af477b8311a1fd68c130374bd7442003c3 (patch)
tree49101f12f5b35574965df39b1cc5a72f5b28f02d /PORTING
parentf79e673f3d3f429cd213043b054c904d23c7151a (diff)
ofproto: Break apart into generic and hardware-specific parts.
In addition to the changes to ofproto, this commit changes all of the instances of "struct flow" in the tree so that the "in_port" member is an OpenFlow port number. Previously, this member was an OpenFlow port number in some cases and an ODP port number in other cases.
Diffstat (limited to 'PORTING')
-rw-r--r--PORTING340
1 files changed, 180 insertions, 160 deletions
diff --git a/PORTING b/PORTING
index 6af9f51d1..b83bf64c5 100644
--- a/PORTING
+++ b/PORTING
@@ -7,6 +7,7 @@ are most likely to be necessary in porting OVS to Unix-like platforms.
(Porting OVS to other kinds of platforms is likely to be more
difficult.)
+
Vocabulary
----------
@@ -26,164 +27,65 @@ is a concordance, indexed by the area of the source tree:
Open vSwitch Architectural Overview
-----------------------------------
-The following diagram shows the conceptual architecture of Open
+The following diagram shows the very high-level architecture of Open
vSwitch from a porter's perspective.
- _ _
- | +-------------------+ |
- | | ovs-vswitchd | |Generic
- | +-------------------+ |code
- userspace | | ofproto | _|
- | +---------+---------+ _
- | | netdev |dpif/wdp | |
- |_ +---||----+----||---+ |Code that
- _ || || |may need
- | +---||-----+---||---+ |porting
- | | |datapath| _|
- kernel | | +--------+
- | | |
- |_ +-------||----------+
- ||
- physical
- NIC
-
-Some of the components are generic. Modulo bugs, these components
-should not need to be modified as part of a port:
-
- - Near the top of the diagram, "ofproto" is the library in Open vSwitch
- that contains the core OpenFlow protocol implementation and switching
- functionality. It is built from source files in the "ofproto"
- directory.
-
- - Above ofproto, "ovs-vswitchd", the main Open vSwitch userspace
- program, is the primary client for ofproto. It is built
- from source files in the "vswitchd" directory of the Open
- vSwitch distribution.
-
- ovs-vswitchd is the most sophisticated of ofproto's clients, but
- ofproto can have other clients as well. Notably, ovs-openflowd,
- in the utilities directory, is much simpler (though less
- capable) than ovs-vswitchd, and it may be easier to get up and
- running as part of a port.
-
-The other components require attention during a port:
-
- - "dpif" or "wdp" is what ofproto uses to directly monitor and
- control a "datapath", which is the term used in OVS for a
- collection of physical or virtual ports that are exposed over
- OpenFlow as a single switch. A datapath implements a flow
- table.
-
- - "netdev" is the interface to "network devices", e.g. eth0 on
- Linux. ofproto expects that every port exposed by a datapath
- has a corresponding netdev that it can open with netdev_open().
-
-The following sections talk about these components in more detail.
-
-Which Branch?
--------------
-
-The architectural diagram shows "dpif" and "wdp" as alternatives.
-These alternatives correspond to the "master" and "wdp" branches,
-respectively, of the Open vSwitch Git repository at
-git://openvswitch.org/openvswitch. Both of these branches currently
-represent reasonable porting targets for different purposes:
-
- - The "master" branch is more mature and better tested. Open
- vSwitch releases are made from this branch, and most OVS
- development and testing occurs on this branch.
-
- - The "wdp" branch has a software architecture that can take
- advantage of hardware with support for wildcards (e.g. TCAMs or
- similar). This branch has known important bugs, but is the basis
- of a few ongoing hardware projects, so we expect the quality to
- improve rapidly.
-
-Since its architecture is better, in the medium to long term we will
-fix the problems in the "wdp" branch and merge it into "master".
-
-In porting OVS, the major difference between the two branches is the
-form of the flow table in the datapath:
-
- - On "master", the "dpif" datapath interface maintains a simple
- flow table, one that does not support any kind of wildcards.
- This flow table essentially acts as a cache. When a packet
- arrives on an interface, the datapath looks for it in this
- exact-match table. If there is a match, then it performs the
- associated actions. If there is no match, the datapath passes
- the packet up to "ofproto", which maintains a flow table that
- supports wildcards. If the packet matches in this flow table,
- then ofproto executes its actions and inserts a new exact-match
- entry into the dpif flow table. (Otherwise, ofproto sends the
- packet to the OpenFlow controller, if one is configured.)
-
- Thus, on the "master" branch, the datapath has little
- opportunity to take advantage of hardware support for wildcards,
- since it is only ever presented with exact-match flow entries.
-
- - On "wdp", the "wdp" datapath interface maintains a flow table
- similar to that of OpenFlow, one that supports wildcards. Thus,
- a wdp datapath can take advantage of hardware support for
- wildcards, since it is free to implement the flow table any way
- it likes.
-
-The following sections describe the two datapath interfaces in a
-little more detail.
-
-dpif: The "master" Branch Datapath
-----------------------------------
-
-struct dpif_class, in lib/dpif-provider.h, defines the
-interfaces required to implement a dpif for new hardware or
-software. That structure contains many function pointers, each
-of which has a comment that is meant to describe its behavior in
-detail. If the requirements are unclear, please report this as
-a bug and we will clarify.
-There are two existing dpif implementations that may serve as
-useful examples during a port:
+ +-------------------+
+ | ovs-vswitchd |<-->ovsdb-server
+ +-------------------+
+ | ofproto |<-->OpenFlow controllers
+ +--------+-+--------+
+ | netdev | | ofproto|
+ +--------+ |provider|
+ | netdev | +--------+
+ |provider|
+ +--------+
+
+Some of the components are generic. Modulo bugs or inadequacies,
+these components should not need to be modified as part of a port:
+
+ - "ovs-vswitchd" is the main Open vSwitch userspace program, in
+ vswitchd/. It reads the desired Open vSwitch configuration from
+ the ovsdb-server program over an IPC channel and passes this
+ configuration down to the "ofproto" library. It also passes
+ certain status and statistical information from ofproto back
+ into the database.
+
+ - "ofproto" is the Open vSwitch library, in ofproto/, that
+ implements an OpenFlow switch. It talks to OpenFlow controllers
+ over the network and to switch hardware or software to an
+ "ofproto provider", explained further below.
+
+ - "netdev" is the Open vSwitch library, in lib/netdev.c, that
+ abstracts interacting with network devices, that is, Ethernet
+ interfaces. The netdev library is a thin layer over "netdev
+ provider" code, explained further below.
+
+The other components may need attention during a port. You will
+almost certainly have to implement a "netdev provider". Depending on
+the type of port you are doing and the desired performance, you may
+also have to implement an "ofproto provider" or a lower-level
+component called a "dpif" provider.
- * lib/dpif-linux.c is a Linux-specific dpif implementation that
- talks to an Open vSwitch-specific kernel module (whose sources
- are in the "datapath" directory). The kernel module performs
- all of the switching work, passing packets that do not match any
- flow table entry up to userspace. This dpif implementation is
- essentially a wrapper around calls to "ioctl".
-
- * lib/dpif-netdev.c is a generic dpif implementation that performs
- all switching internally. It delegates most of its work to the
- "netdev" library (described below). Using dpif-netdev, instead
- of writing a new dpif, can be a simple way to get OVS up and
- running on new platforms, but other solutions are likely to
- yield higher performance.
-
-"wdp": The "wdp" Branch Datapath
---------------------------------
-
-struct wdp_class, in ofproto/wdp-provider.h, defines the interfaces
-required to implement a wdp ("wildcarded datapath") for new hardware
-or software. That structure contains many function pointers, each of
-which has a comment that is meant to describe its behavior in detail.
-If the requirements are unclear, please report this as a bug and we
-will clarify.
+The following sections talk about these components in more detail.
-The wdp interface is preliminary. Please let us know if it seems
-unsuitable for your purpose. We will try to improve it.
-There is currently only one wdp implementation:
+Writing a netdev Provider
+-------------------------
- * ofproto/wdp-xflow.c is an adaptation of "master" branch code
- that breaks wildcarded flows up into exact-match flows in the
- same way that ofproto always does on the "master" branch. It
- delegates its work to exact-match datapath implementations whose
- interfaces are identical to "master" branch datapaths, except
- that names have been changed from "dpif" to "xfif" ("exact-match
- flow interface") and similar.
+A "netdev provider" implements an operating system and hardware
+specific interface to "network devices", e.g. eth0 on Linux. Open
+vSwitch must be able to open each port on a switch as a netdev, so you
+will need to implement a "netdev provider" that works with your switch
+hardware and software.
-"netdev": Interface to network devices
---------------------------------------
+struct netdev_class, in lib/netdev-provider.h, defines the interfaces
+required to implement a netdev. That structure contains many function
+pointers, each of which has a comment that is meant to describe its
+behavior in detail. If the requirements are unclear, please report
+this as a bug.
-The netdev interface can be roughly divided into functionality for the
-following purposes:
+The netdev interface can be divided into a few rough categories:
* Functions required to properly implement OpenFlow features. For
example, OpenFlow requires the ability to report the Ethernet
@@ -196,15 +98,9 @@ following purposes:
table. These functions must be implemented if the corresponding
OVS features are to work, but may be omitted initially.
- * Functions that may be needed in some implementations but not
- others. The dpif-netdev described above, for example, needs to
- be able to send and receive packets on a netdev.
-
-struct netdev_class, in lib/netdev-provider.h, defines the interfaces
-required to implement a netdev. That structure contains many function
-pointers, each of which has a comment that is meant to describe its
-behavior in detail. If the requirements are unclear, please report
-this as a bug and we will clarify.
+ * Functions needed in some implementations but not in others. For
+ example, most kinds of ports (see below) do not need
+ functionality to receive packets from a network device.
The existing netdev implementations may serve as useful examples
during a port:
@@ -213,14 +109,137 @@ during a port:
network devices, using Linux kernel calls. It may be a good
place to start for full-featured netdev implementations.
- * lib/netdev-vport.c provides support for "virtual ports"
+ * lib/netdev-vport.c provides support for "virtual ports"
implemented by the Open vSwitch datapath module for the Linux
kernel. This may serve as a model for minimal netdev
implementations.
+ * lib/netdev-dummy.c is a fake netdev implementation useful only
+ for testing.
+
+
+Porting Strategies
+------------------
+
+After a netdev provider has been implemented for a system's network
+devices, you may choose among three basic porting strategies.
+
+The lowest-effort strategy is to use the "userspace switch"
+implementation built into Open vSwitch. This ought to work, without
+writing any more code, as long as the netdev provider that you
+implemented supports receiving packets. It yields poor performance,
+however, because every packet passes through the ovs-vswitchd process.
+See INSTALL.userspace for instructions on how to configure a userspace
+switch.
+
+If the userspace switch is not the right choice for your port, then
+you will have to write more code. You may implement either an
+"ofproto provider" or a "dpif provider". Which you should choose
+depends on a few different factors:
+
+ * Only an ofproto provider can take full advantage of hardware
+ with built-in support for wildcards (e.g. an ACL table or a
+ TCAM).
+
+ * A dpif provider can take advantage of the Open vSwitch built-in
+ implementations of bonding, LACP, 802.1ag, 802.1Q VLANs, and
+ other features. An ofproto provider has to provide its own
+ implementations, if the hardware can support them at all.
+
+ * A dpif provider is usually easier to implement.
+
+The following sections describe how to implement each kind of port.
+
+
+ofproto Providers
+-----------------
+
+An "ofproto provider" is what ofproto uses to directly monitor and
+control an OpenFlow-capable switch. struct ofproto_class, in
+ofproto/private.h, defines the interfaces to implement a ofproto
+provider for new hardware or software. That structure contains many
+function pointers, each of which has a comment that is meant to
+describe its behavior in detail. If the requirements are unclear,
+please report this as a bug.
+
+The ofproto provider interface is preliminary. Please let us know if
+it seems unsuitable for your purpose. We will try to improve it.
+
+
+Writing a dpif Provider
+-----------------------
+
+Open vSwitch has a built-in ofproto provider named "ofproto-dpif",
+which is built on top of a library for manipulating datapaths, called
+"dpif". A "datapath" is a simple flow table, one that supports only
+exact-match flows, that is, flows without wildcards. When a packet
+arrives on a network device, the datapath looks for it in this
+exact-match table. If there is a match, then it performs the
+associated actions. If there is no match, the datapath passes the
+packet up to ofproto-dpif, which maintains an OpenFlow flow table
+(that supports wildcards). If the packet matches in this flow table,
+then ofproto-dpif executes its actions and inserts a new exact-match
+entry into the dpif flow table. (Otherwise, ofproto-dpif passes the
+packet up to ofproto to send the packet to the OpenFlow controller, if
+one is configured.)
+
+The "dpif" library in turn delegates much of its functionality to a
+"dpif provider". The following diagram shows how dpif providers fit
+into the Open vSwitch architecture:
+
+ _
+ | +-------------------+
+ | | ovs-vswitchd |<-->ovsdb-server
+ | +-------------------+
+ | | ofproto |<-->OpenFlow controllers
+ | +--------+-+--------+
+ | | netdev | |ofproto-|
+ userspace | +--------+ | dpif |
+ | | netdev | +--------+
+ | |provider| | dpif |
+ | +---||---+ +--------+
+ | || | dpif |
+ | || |provider|
+ |_ || +---||---+
+ || ||
+ _ +---||-----+---||---+
+ | | |datapath|
+ kernel | | +--------+
+ | | |
+ |_ +--------||---------+
+ ||
+ physical
+ NIC
+
+struct dpif_class, in lib/dpif-provider.h, defines the interfaces
+required to implement a dpif provider for new hardware or software.
+That structure contains many function pointers, each of which has a
+comment that is meant to describe its behavior in detail. If the
+requirements are unclear, please report this as a bug.
+
+There are two existing dpif implementations that may serve as
+useful examples during a port:
+
+ * lib/dpif-linux.c is a Linux-specific dpif implementation that
+ talks to an Open vSwitch-specific kernel module (whose sources
+ are in the "datapath" directory). The kernel module performs
+ all of the switching work, passing packets that do not match any
+ flow table entry up to userspace. This dpif implementation is
+ essentially a wrapper around calls into the kernel module.
+
+ * lib/dpif-netdev.c is a generic dpif implementation that performs
+ all switching internally. This is how the Open vSwitch
+ userspace switch is implemented.
+
+
Miscellaneous Notes
-------------------
+ovs-vswitchd is the most sophisticated of ofproto's clients, but
+ofproto can have other clients as well. ovs-openflowd, in the
+utilities directory, is much simpler than ovs-vswitchd. It may be
+easier to initially bring up ovs-openflowd as part of a port.
+
lib/entropy.c assumes that it can obtain high-quality random number
seeds at startup by reading from /dev/urandom. You will need to
modify it if this is not true on your platform.
@@ -228,6 +247,7 @@ modify it if this is not true on your platform.
vswitchd/system-stats.c only knows how to obtain some statistics on
Linux. Optionally you may implement them for your platform as well.
+
Questions
---------